BQKKY - PH/PC02 CONDITIONING SOLUTION 06857

  • MSDS: BQKKY
  • Manufacturer: NOVA BIOMEDICAL CORP
  • Product Name: PH/PC02 CONDITIONING SOLUTION 06857
  • National Stock Number: 6630-01-285-0180
Product Identification

Product ID:PH/PC02 CONDITIONING SOLUTION 06857
MSDS Date:01/29/1991
FSC:6630
NIIN:01-285-0180
MSDS Number: BQKKY

Responsible Party
NOVA BIOMEDICAL CORP
200 PROSPECT ST
WALTHAM, MA 02154-9141
US

Emergency Phone: 617-894-0800

Info Phone: 617-894-0800

Cage: 59924

Contractor
NOVA BIOMEDICAL CORP
WALTHAM, MA 02154-9141 US

Telephone: 617-894-0800

Cage: 59924

Ingredients

HYDROCHLORIC ACID, HYDROGEN CHLORIDE, MURIATIC ACID

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 0.4%

OSHA PEL 5 PPM

ACGIH TLV: C 11 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: IRRITATION OF RESPIRATORY
TRACT. SKIN/EYES: IRRITATION & BURNING.
Explanation of Carcinogenicity:NONE

First Aid

First Aid:INGESTION: DON'T INDUCE VOMITING. IF CONSCIOUS, GIVE WATER,
MILK OR MILK OF MAGNESIA. EYES/SKIN: IMMEDIATELY FLUSH W/WATER.
OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
FIRE.

Accidental Release

Spill Release Procedures:WEARING SUITABLE PROTECTIVE CLOTHING, ABSORB
SPILLED MATERIAL ON VERMICULITE. PLACE IN FIBER CARTON. WASH SPILL
AREA WELL W/SOAP & WATER.

Handling

Handling and Storage Precautions:AVOID CONTACT W/SKIN.

Exposure Controls

Respiratory Protection:GAS MASK W/ACID VAP0R CANISTER OR SELF-BREATHING
APPARATUS.
Ventilation:LOCAL EXHAUST/MECHANICAL (GENERAL): REQUIRED.
Protective Gloves:RUBBER
Eye Protection:GOGGLES
Other Protective Equipment:AS NECESSARY
Work Hygienic Practices:GOOD LABORATORY PRACTICE.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:103C
Spec Gravity:1.05
Appearance and Odor:CLEAR, COLORLESS SOLUTION, PUNGENT ODOR OF HYDROGEN
CHLORIDE.

Stability

Stability Indicator/Materials to Avoid:YES
ALKALIS & METALS
Stability Condition to Avoid:HEAT

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/ALL FEDERAL, STATE, &
LOCAL ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.